Skip to content
Home
About
Trans-West Line Card
Siemens Belt Scales Line Card
Valmet Line Card
Ashcroft Mining & Metallurgy Line Card
Siemens Mining Line Card
Products
Instrumentation & Controls
Analytical
Chlorine
pH/ORP/Conductivity
Sodium
Turbidity
Flow
Clamp-On Ultrasonic
Electromagnetic
Vortex
Mass Flow Coriolis
Level
Radar Transmitters
Ultrasonic Transmitters
Pressure
Differential
Gauge
Switches
Transmitters
Temperature
Indicators
Weighing
Integrators
Mechanical
Valves
Ball Valves
Butterfly Valves
Gate Valves
Knife Valves
Solenoid Valves
Actuation
Electric Actuation
Weight & Belt Weighing Systems
Level & Distance Measurement
Process Sensors & Transmitters
Manufacturers
Industries
Mining Sector
Pulp & Paper
Oil and Gas
Waste Water
Water Treatment
Fertilizer
Demo Trailer
Home
About
Trans-West Line Card
Siemens Belt Scales Line Card
Valmet Line Card
Ashcroft Mining & Metallurgy Line Card
Siemens Mining Line Card
Products
Instrumentation & Controls
Analytical
Chlorine
pH/ORP/Conductivity
Sodium
Turbidity
Flow
Clamp-On Ultrasonic
Electromagnetic
Vortex
Mass Flow Coriolis
Level
Radar Transmitters
Ultrasonic Transmitters
Pressure
Differential
Gauge
Switches
Transmitters
Temperature
Indicators
Weighing
Integrators
Mechanical
Valves
Ball Valves
Butterfly Valves
Gate Valves
Knife Valves
Solenoid Valves
Actuation
Electric Actuation
Weight & Belt Weighing Systems
Level & Distance Measurement
Process Sensors & Transmitters
Manufacturers
Industries
Mining Sector
Pulp & Paper
Oil and Gas
Waste Water
Water Treatment
Fertilizer
Demo Trailer
Contact
Ashcroft® – Panel Meter – DM61
Home
»
Shop
»
Ashcroft® – Panel Meter – DM61
Home
/
Metering
/ Ashcroft® – Panel Meter – DM61
Ashcroft® – Panel Meter – DM61
Brand
Ashcroft Inc
Humidity
0 to 90 % Relative Humidity, Non-Condensing
Electrical Connectors
12 to 22 AWG Wire
Digital I/O
RJ45 for External Relays
Screw Terminal
Serial Communication Adaptor Kit
Approvals & Certifications
ISO 9001
CE
UL E160849, 508 Industrial Control Equipment
Isolation
4 kV Input/Output-to-Power-Line
500 V Input to Output or Output to P+ Supply
Channels
4-Digital Inputs & 4-Digital Outputs Per Module
Accuracy
± 0.03 % of Span ± 1 Count
± 0.1 % of Span ± 0.004 mA
Square Root & Programmable Exponent: 10 to 100 % of Calibrated Span
Temperature Coefficient
0.005 % of Calibrated Span/°C, Max.
0.01 % of Calibrated Span/°C, Max.
Power Options
85-265 Vac, 50/60 Hz
90-265 Vdc, 20 W, Max.
Jumper Selectable 12-24 Vdc ± 10 %, 15 W, Max.
Load
Inductive Load: 1-1/4 hp at 125-250 Vac
Resistive Load: 3 A at 120-250 Vac
Resistive Load: 3 A at 30 Vdc
Enclosure, Body Material
1/8 DIN, High Impact Plastic, UL 94V-0 (Black)
Input
± 10 Vdc (0-5 V, 1-5 V, 0-10 V)
0-20 mA
4-20 mA
Digital Input Logic: 0-1.25 Vdc Low
Digital Input Logic: 3-5 Vdc High
Overload: 30 Vdc, Max.
Operating Temperature
-40° to 65° C (-40° to 149° F)
Display
2 Lines of 6-Digits
-99999 to 999999
Red LEDs with Leading 0 Blanking
Upper: 0.60” High, Lower: 0.46” High
Power Supply
External Loop Power Supply: 35 Vdc, Max.
Isolated Transmitter: 10 Vdc at 50 mA – Max.
Isolated Transmitter: 12-24 Vdc at 100 mA – Max.
Isolated Transmitter: 24 Vdc ± 5 % at 200 mA – Max.
Isolated Transmitter: 5 Vdc at 50 mA – Max.
Communication
Baud Rate: 300 to 19,200 bit/sec
Data Length: 8-bits (1 Start Bit, 1 or 2 Stop Bits)
Modbus RTU
Deadband
0 to 100 % of Span
Range
Scaling Range: 1 to 23 mA for Any Display Range
Storage Temperature
-40° to 85° C (-40° to 185° F)
Loop Resistance
Output Loop Resistance: 10 to 700 ohms at 24 Vdc
Output Loop Resistance: 100 to 1,200 ohms at 35 Vdc (External)
Environmental Protection
Front Panel: IP65
Front Panel: NEMA 4X
IP66
Function
High & Low Alarms
Linear
Math Function
Password Protection
Programmable Exponent
Round Horizontal Tank Volume Calculation
Square Root
Output
Analog Output Programming: 23 mA – Max.
Digital Output Logic: 0-0.4 Vdc Low
Digital Output Logic: 3.1-3.3 Vdc High
Thermal Drift
0.4 µA/°C, Max.
0.8 µA/°C, Max.
Update Time
200 milliseconds
Delay Time
0 to 999.9 seconds
Transmit Time Delay: 0 to 199 milliseconds or Transmitter Always on for RS-422
Turn Around Delay: < 2 milliseconds
Rating
Relay: 2 or 4 SPDT (Form C)
Relay: 4 SPST (Form A)
Programming
Cloning Using Copy Function
Digital Inputs
Modbus Registers
Panel Buttons
PC & DPM ProView Software
Input Impedance
Current Ranges: 50 to 100 ohms (Depending on Resettable Fuse Impedance)
Voltage Ranges: > 1 megaohms
Linearization
Multi-Point Linearization: 2 to 32-Points for PV or PV1
Multi-Point Linearization: 2 to 8-Points for PV2 (Dual-Scale Level Feature)
Mounting
Panel Mount Bracket
Output Noise
Normal Mode Rejection: > 60 dB at 50/60 Hz
Current
Fuse: 5 A, Max.
Sink: 1.5 mA Min.
Source: 10 mA – Max.
Relay Operation
Automatic (Non-Latching)
Fail-safe
Latching (Requires Manual Acknowledge)
Off (Disable Unused Relays & Enable Interlock Feature, Manual ON/OFF Control Mode)
Pump Alternation Control (2 to 8 Relays)
Sampling (Based on Time)